Korean J Obstet Gynecol Search

CLOSE


Korean Journal of Obstetrics & Gynecology 2004;47(10):1960-1964.
Published online October 1, 2004.
Misplaced IUD.
Ji Hyang Choi, Jung Min Suh, Hee Joong Lee, Joon Hwan Oh, Gui SeRa Lee, Soo Young Hur, Jong Chul Shin, Sa Jin Kim
Department of Obstetrics and Gynecology, Holy Family Hospital, College of Medicine, The Catholic University of Korea, Korea.
Abstract
OBJECTIVE
To study intrauterine or extrauterine misplacement of intrauterine devices in respect to their usage in diagnosis and therapy via retrospective analysis. METHODS: Data from 1993 to 2000 on a total of 32 patients from seven Catholic University branch hospitals who had been admitted to treat IUDs which had misplaced to intrauterine or extrauterine locations were analyzed for usage in a retrospective study. RESULTS: The data for intrauterine and extrauterine misplacement revealed no significant difference between from the statistical average in relation to age, parity and duration of insertion. In terms of removal method, all 15 patients with extrauterine misplacement underwent surgical extraction by open or laparascopic method under general anesthesia, but those patients with intrauterine misplacement had their device removed after cervical dilatation with a laminaria using local anesthesia. Concerning diagnosis, 81.2% of extrauterine misplacement were diagnosed using x-ray while 58% of intrauterine misplacement were diagnosed using vaginal US. The result of the Fisher's exact test showed a significant difference (p=0.043) in the rate of diagnosis for intrauterine and extrauterine misplacement of IUDs. Also, the results of multi-variable analysis performed for logistical regression analysis showed that intrauterine misplacement occurred 1.23 times more frequently than extrauterine misplacement. CONCLUSION: Further studies are required on a broader patient population, on more types of IUDs and with time variables taken into account. Despite more research, prevention of complications such as misplacement remains the most appealing situation, being influenced by such factors as technical skill of the physician inserting the IUD, appropriate duration of insertion and proper patient education.
Key Words: Intrauterine device (IUD), misplacement
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 685 View
  • 10 Download
Related articles in Obstet Gynecol Sci

Misplaced IUD.2004 March;47(3)



ABOUT
ARTICLE & TOPICS
Article category

Browse all articles >

Topics

Browse all articles >

BROWSE ARTICLES
POLICY
FOR CONTRIBUTORS
Editorial Office
4th Floor, 36 Gangnam-daero 132-gil, Gangnam-gu, Seoul 06044, Korea.
Tel: +82-2-2266-7238    Fax: +82-2-3445-2440    E-mail: journal@ogscience.org                

Copyright © 2024 by Korean Society of Obstetrics and Gynecology.

Developed in M2PI

Close layer
prev next